XN-550

Add to wishlist
Category:

Automated compact 6-part differential haematology analyser. With the XN-550 you can run single samples safely in closed mode. It has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen that makes it easy to operate

XN-550

  • Compact 6-part differential analyser

  • Throughput of 70 samples per hour

  • Dedicated STAT sampling mode

  • Fully integrated IPU including LCD colour touchscreen

  • Only 25 µL aspiration volume in whole blood mode

  • More than just CBC + DIFF – added clinical values available

  • Best-in-class diagnostics tailored to small and mid-sized laboratories

Registered Under Act 737 (IVDB17531114618)

With the XN-550 you can run single samples safely in closed mode. It The compact 6-part differential analyser has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen – so you do not need a separate computer to operate the analyser. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future beyond just CBC + DIFF, it can be upgraded by adding new clinical and productivity values.

Dimensions / weights
  • W x H x D [mm / kg]
  • XN-550: 450 x 450 x 660 / approx. 53 kg
  • Monitor: 267 xx 240 x 205 / approx. 3kg
Throughput
  • CBC + DIFF: up to 70 samples/hour
  • CBC + DIFF + RET: up to 35 samples/hour
  • Body fluide mode: up to 30 samples/hour
Aspiration volume
  • 25 µL in WB / Low WBC mode,
  • 70 µL in PD and BF mode
Analysis parameters
  • Whole Blood
    WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%
  • With RET (optional)
    RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He
  • Body Fluids (optional)
    WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles
  • WBC DIFF/RET: Fluorescence Flow Cytometry
  • WBC: Flow Cytometry
  • RBC/PLT: DC Impedance method with hydrodynamic focusing
  • HGB: Cyanide-free SLS method
Data storage capacities
  • Results: 100,000 samples
  • Patient information: 10,000 records
  • Calibration history: 20 times/ module
  • QC files: 99 files including XbarM
  • QC plots: 300 plots / file
User maintenance
  • Daily shutdown
  • Weekly cleaning sequence with Cellclean or Cellclean Auto
Features & Benefits

With the XN-550 you can run single samples safely in closed mode. It The compact 6-part differential analyser has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen – so you do not need a separate computer to operate the analyser. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future beyond just CBC + DIFF, it can be upgraded by adding new clinical and productivity values.

Specifications
Dimensions / weights
  • W x H x D [mm / kg]
  • XN-550: 450 x 450 x 660 / approx. 53 kg
  • Monitor: 267 xx 240 x 205 / approx. 3kg
Throughput
  • CBC + DIFF: up to 70 samples/hour
  • CBC + DIFF + RET: up to 35 samples/hour
  • Body fluide mode: up to 30 samples/hour
Aspiration volume
  • 25 µL in WB / Low WBC mode,
  • 70 µL in PD and BF mode
Analysis parameters
  • Whole Blood
    WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG%
  • With RET (optional)
    RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He
  • Body Fluids (optional)
    WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles
  • WBC DIFF/RET: Fluorescence Flow Cytometry
  • WBC: Flow Cytometry
  • RBC/PLT: DC Impedance method with hydrodynamic focusing
  • HGB: Cyanide-free SLS method
Data storage capacities
  • Results: 100,000 samples
  • Patient information: 10,000 records
  • Calibration history: 20 times/ module
  • QC files: 99 files including XbarM
  • QC plots: 300 plots / file
User maintenance
  • Daily shutdown
  • Weekly cleaning sequence with Cellclean or Cellclean Auto