Automated compact 6-part differential haematology analyser. With the XN-450 you can run single samples safely in closed mode. It has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen that makes it easy to operate.
XN-450
Compact 6-part differential analyser
Throughput of 70 samples per hour
Single sample analysis in closed mode
Fully integrated IPU including LCD colour touchscreen
Only 25 µL aspiration volume in whole blood mode
More than just CBC + DIFF – added clinical values available
Best-in-class diagnostics tailored to small and mid-sized laboratories
Registered Under Act 737 (IVDB17531114618)
With the XN-450 you can run single samples safely in closed mode. The compact 6-part differential analyser has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen – so you do not need a separate computer to operate the analyser. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future beyond just CBC + DIFF, it can be upgraded by adding new clinical and productivity values.
Dimensions / weights |
|
Throughput |
|
Aspiration volume |
|
Analysis parameters |
|
Measurement principles |
|
Data storage capacities |
|
User maintenance |
|
- Features & Benefits
-
With the XN-450 you can run single samples safely in closed mode. The compact 6-part differential analyser has a fully integrated IPU (information-processing unit) including an LCD colour touchscreen – so you do not need a separate computer to operate the analyser. It incorporates the proven Sysmex technologies of fluorescence flow cytometry, hydrodynamic focussing and our cyanide-free SLS method for determining haemoglobin. Ready for the future beyond just CBC + DIFF, it can be upgraded by adding new clinical and productivity values.
- Specifications
-
Dimensions / weights - W x H x D [mm / kg]
- XN-450: 450 x 440 x 460 / approx. 35 kg
Throughput - CBC + DIFF: up to 70 samples/hour
- CBC + DIFF + RET: up to 35 samples/hour
- Body fluide mode: up to 30 samples/hour
Aspiration volume - 25 µL in WB / Low WBC mode,
- 70 µL in PD and BF mode
Analysis parameters - Whole Blood
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, PDW, MPV, P-LCR, PCT, NEUT#, LYMPH#, MONO#, EO#, BASO#, NEUT%, LYMPH%, MONO%, EO%, BASO%, IG#, IG% - With RET (optional)
RET#, RET%, IRF, LFR, MFR, HFR, RET-He, PLT-O, IPF#, IPF, RBC-He, Delta-He, HYPO-He, HYPER-He - Body Fluids (optional)
WBC-BF, RBC-BF, MN#, PMN#, MN%, PMN%, TC-BF#
Measurement principles - WBC DIFF/RET: Fluorescence Flow Cytometry
- WBC: Flow Cytometry
- RBC/PLT: DC Impedance method with hydrodynamic focusing
- HGB: Cyanide-free SLS method
Data storage capacities - Results: 100,000 samples
- Patient information: 10,000 records
- Calibration history: 20 times/ module
- QC files: 99 files including XbarM
- QC plots: 300 plots / file
User maintenance - Daily shutdown
- Weekly cleaning sequence with Cellclean or Cellclean Auto
- Documents