The CA-660 analyser is a compact, fully automated coagulation analyser system which utilises the proven optical detection technology and the same reagent system of Sysmex coagulation family analysers. It (Sysmex CA-660 Analyser) offers high performance automation for both routine specialty haemostasis testing such as D-dimer and von Willebrand Factor activity. Combining the simplicity of use and diagnostic power, the laboratory can be confident that they continuously stay ahead in haemostasis testing with the Sysmex CA-660 analyser.
CA-660
Sysmex’s smallest fully automated haemostasis analyser that offers clotting, chromogenic and immunological (turbidimetric) detection principles
Registered Under Act 737 (IVDC8240021-69698)
The Sysmex CA-660 analyser offers an economical, automated solution for low-medium volume laboratories to achieve analytical excellence, workflow efficiency and improved data management.
Analytical excellence
Workflow efficiency
Excellent data management
Detection principles | Clotting: scattered light detection method Chromogenic: colorimetric method Immunologic: Latex-enhanced turbidimetric method |
Detection channel/method | 4 LEDs with wavelength 660 nm for clotting assays 1 LED with wavelength 405 nm for chromogenic assay 1 LED with wavelength 575 nm for immunoassay |
Parameters | 5-parameter random analysis simultaneously |
Throughput | PT: 60 tests/hour PT/APTT/Fbg: 42 tests/hour |
Sampling | Continuous-access 10 sample rack 1 dedicated STAT position |
Reagent holder | 13 positions (with 4 cooled and 3 dedicated to diluents, buffers or cleaning reagents) |
Reference curves | 1 reference curve per parameter 1 lot per parameter Maximum 14 parameters |
Quality control | X-bar control, Levy-Jennings control 6 files with maximum 180 points each |
Data storage | Up to 600 samples / maximum 3,000 tests |
Printer | Internal printer |
Dimensions (WxHxD)/weights | 566 x 490 x 490 mm, 42 kg (approximate) |
- Features & Benefits
-
The Sysmex CA-660 analyser offers an economical, automated solution for low-medium volume laboratories to achieve analytical excellence, workflow efficiency and improved data management.
Analytical excellence
Workflow efficiency
Excellent data management
- Assay
-
- Specifications
-
Detection principles Clotting: scattered light detection method
Chromogenic: colorimetric method
Immunologic: Latex-enhanced turbidimetric methodDetection channel/method 4 LEDs with wavelength 660 nm for clotting assays
1 LED with wavelength 405 nm for chromogenic assay
1 LED with wavelength 575 nm for immunoassayParameters 5-parameter random
analysis simultaneouslyThroughput PT: 60 tests/hour
PT/APTT/Fbg: 42 tests/hourSampling Continuous-access 10 sample rack
1 dedicated STAT positionReagent holder 13 positions (with 4 cooled and 3 dedicated to diluents, buffers or cleaning reagents) Reference curves 1 reference curve per parameter
1 lot per parameter
Maximum 14 parametersQuality control X-bar control, Levy-Jennings control
6 files with maximum 180 points eachData storage Up to 600 samples / maximum 3,000 tests Printer Internal printer Dimensions (WxHxD)/weights 566 x 490 x 490 mm, 42 kg (approximate) - Documents