CA-600

Add to wishlist
Category:

The CA-600 system is a compact, fully automated coagulation analyser which utilises the proven optical detection technology and the same reagent system of Sysmex coagulation family analysers. It offers high performance automation for clotting assays in a true random access. Combining the simplicity of use and diagnostic power, the laboratory can be confident that they continuously stay ahead in haemostasis testing with the CA-600.

CA-600

Sysmex’s smallest fully automated haemostasis analyser that offers clotting detection principle.

Registered Under Act 737 (IVDC8240021-69698)

The CA-600 system offers an economical, automated solution for low-medium volume laboratories to achieve analytical excellence, workflow efficiency and improved data management.

Analytical excellence

  • The imprecision of manual coagulation testing is high, with coefficient of variation (CV) of greater than 20%; and duplicate measurement is thus recommended. With CA-600, fully automated coagulation analyser, the accuracy has greatly improved, attaining a CV of less than 5%, and as low as 1% for some tests.
  • Based upon its predecessors, the proven optical based detection principle allows operator to visualise the clot formation, and together with its in-built checking algorithm, detect any unusual in-vitro clot formation to avoid the report of inaccurate results.

Workflow Efficiency

  • Medical Technologists can now focus on higher value aspects of laboratory testing such as pre-analytics or post-analytics that require focused attention.
  • Simultaneous analysis of up to 5 parameters and optimal throughput allow laboratories to perform routine and specialty testing in greater efficiency.

Excellent data management

  • Sample barcode reader simplifies sample ID processing and enables security and integrity of patient records.
  • Handheld 2D barcode reader simplifies the data entry process for ISI, control and calibrator values, lot numbers, and expiry information.
  • Data up to 600 samples or 3000 tests can be stored onboard for easy retrieval for review.
  • PT: Dade Innovin, Thromborel S
  • APTT: Dade Actin, Dade Actin FS, Dade Actin FSL, Pathromtin SL
  • Fibrinogen: Multifibren U, Dade Thrombin, Dade Fibrinogen Determination Reagent
  • Thrombin Time: Test Thrombin, Thromboclotin
  • Batroxobin Time: Batroxobin
  • Factor Deficiency: Factor II, V, VII, VIII, IX, X, XI, XII
  • Lupus Anticoagulant: LA1 screen, LA2 confirmation
  • Protein C Pathway: ProC Global, Protein C Reagent
Detection principles Clotting: scattered light detection method
Detection channel/method 4 LEDs with wavelength 660 nm for clotting assays
Parameters 5-parameter random
analysis simultaneously
Throughput PT: 60 tests/hour
PT/APTT/Fbg: 42 tests/hour
Sampling Continuous-access 10 sample rack
1 dedicated STAT position
Reagent holder 13 positions (with 4 cooled and 3 dedicated to diluents, buffers or cleaning reagents)
Reference curves 1 reference curve per parameter
1 lot per parameter
Maximum 14 parameters
Quality control X-bar control, Levy-Jennings control
6 files with maximum 180 points each
Data storage Up to 600 samples / maximum 3,000 tests
Printer Internal printer
Dimensions (WxHxD)/weights 566 x 490 x 490 mm, 42 kg (approximate)
Features & Benefits

The CA-600 system offers an economical, automated solution for low-medium volume laboratories to achieve analytical excellence, workflow efficiency and improved data management.

Analytical excellence

  • The imprecision of manual coagulation testing is high, with coefficient of variation (CV) of greater than 20%; and duplicate measurement is thus recommended. With CA-600, fully automated coagulation analyser, the accuracy has greatly improved, attaining a CV of less than 5%, and as low as 1% for some tests.
  • Based upon its predecessors, the proven optical based detection principle allows operator to visualise the clot formation, and together with its in-built checking algorithm, detect any unusual in-vitro clot formation to avoid the report of inaccurate results.

Workflow Efficiency

  • Medical Technologists can now focus on higher value aspects of laboratory testing such as pre-analytics or post-analytics that require focused attention.
  • Simultaneous analysis of up to 5 parameters and optimal throughput allow laboratories to perform routine and specialty testing in greater efficiency.

Excellent data management

  • Sample barcode reader simplifies sample ID processing and enables security and integrity of patient records.
  • Handheld 2D barcode reader simplifies the data entry process for ISI, control and calibrator values, lot numbers, and expiry information.
  • Data up to 600 samples or 3000 tests can be stored onboard for easy retrieval for review.
Assay
  • PT: Dade Innovin, Thromborel S
  • APTT: Dade Actin, Dade Actin FS, Dade Actin FSL, Pathromtin SL
  • Fibrinogen: Multifibren U, Dade Thrombin, Dade Fibrinogen Determination Reagent
  • Thrombin Time: Test Thrombin, Thromboclotin
  • Batroxobin Time: Batroxobin
  • Factor Deficiency: Factor II, V, VII, VIII, IX, X, XI, XII
  • Lupus Anticoagulant: LA1 screen, LA2 confirmation
  • Protein C Pathway: ProC Global, Protein C Reagent
Specifications
Detection principles Clotting: scattered light detection method
Detection channel/method 4 LEDs with wavelength 660 nm for clotting assays
Parameters 5-parameter random
analysis simultaneously
Throughput PT: 60 tests/hour
PT/APTT/Fbg: 42 tests/hour
Sampling Continuous-access 10 sample rack
1 dedicated STAT position
Reagent holder 13 positions (with 4 cooled and 3 dedicated to diluents, buffers or cleaning reagents)
Reference curves 1 reference curve per parameter
1 lot per parameter
Maximum 14 parameters
Quality control X-bar control, Levy-Jennings control
6 files with maximum 180 points each
Data storage Up to 600 samples / maximum 3,000 tests
Printer Internal printer
Dimensions (WxHxD)/weights 566 x 490 x 490 mm, 42 kg (approximate)