TS-01/TA-01

Add to wishlist
Category:

TS-01/ TA-01: Compact Sample Handling Management

The compact TA-01 and TS-01 offers split functionality of samples archival and sorting integrated in the XR-9000 automation line. The duo promotes overall efficiency in laboratories with limited space and budget but in need of compact automation in post-analytical handling & storage of EDTA samples (TA-01) or sorting of EDTA tubes for further testing (i.e., ESR, HbA1c)*.

*Selected model and countries. Please contact your local Sysmex Representative.

TS-01/TA-01

TS-01

Registered Under Act 737 (IVDB6506724-170755)

TS-01/TA-01

TA-01

Registered Under Act 737 (IVDB6506724-170755)

TS-01 / TA-01 Benefits:

  • Increased efficiency with highly customisable and automated post-analytical processing of EDTA tubes for slide preparation or further test or storage.
  • Hands-free sorting and archiving
  • Compact and affordable solution
  • Connectivity to major TLA systems possible

TS-01

Dimension (mm)
  • 390 (W) x 1150 (D) x 1545 (H)
  • When including ST-40: 660mm (W)
Throughput
  • 66 racks/h
  • Under the following conditions:
    • Sorting ratio 20%
    • Set 10 samples on every rack
Maximum # of connectable XR analyzers
  • 6 units

TA-01

Dimension (mm)
  • 650 (W) x 1150 (D) x 1545 (H)
  • When including ST-40: 920mm (W)
Throughput
  • 50 racks/h
  • Under the following conditions:
    • Sorting ratio 20%
    • Set 10 samples on every rack
Maximum # of connectable XR analyzers
  • 6 units
Storage
  • Up to 600 samples in up to 30 programmable storage areas
null

Sysmex XR-Series Brochure

Download »

Features & Benefits

TS-01 / TA-01 Benefits:

  • Increased efficiency with highly customisable and automated post-analytical processing of EDTA tubes for slide preparation or further test or storage.
  • Hands-free sorting and archiving
  • Compact and affordable solution
  • Connectivity to major TLA systems possible
Specifications

TS-01

Dimension (mm)
  • 390 (W) x 1150 (D) x 1545 (H)
  • When including ST-40: 660mm (W)
Throughput
  • 66 racks/h
  • Under the following conditions:
    • Sorting ratio 20%
    • Set 10 samples on every rack
Maximum # of connectable XR analyzers
  • 6 units

TA-01

Dimension (mm)
  • 650 (W) x 1150 (D) x 1545 (H)
  • When including ST-40: 920mm (W)
Throughput
  • 50 racks/h
  • Under the following conditions:
    • Sorting ratio 20%
    • Set 10 samples on every rack
Maximum # of connectable XR analyzers
  • 6 units
Storage
  • Up to 600 samples in up to 30 programmable storage areas
Document
null

Sysmex XR-Series Brochure

Download »